Get Price

Bacti-cinerator Sterilizer BSTE-102

Bacti-cinerator Sterilizer
Bacti-cinerator Sterilizer uses infrared heat sterilization, because it is easy to use, simple to operate, no open flame, no fear of wind, substitute alcohol lamp, safe to use, can be widely used in the environment of biosafety cabinet, purification workbenches, suction fans, and mobile vehicles, for microbiological experiments.
  • Based on the principle of electronic infrared, the products are widely used in the sterilization of inoculation rings or inoculation needles, completely replacing alcohol lamps.
  • The temperature inside the heating hole can reach 800 °C or above, sterilization takes only 5-7 seconds and sterilization is thorough. The product can be used in an anaerobic chamber.
  • Small volume, light weight, appearance and easy to clean. Heating body can adjust angle, easy operation.
  • Organic substances in the ceramic funnel pipe depths ashing prevent infectious spatter and cross contamination.
Old SKU: BFA1CZ1
Specifications Features Photos Manual Get Quote

Specifications

ModelBSTE-102
Center Max. Temp.825°C±50°C
Low Level Temp.480°C
Heating Speed20min (to max. temp.)
Max. Sterilize DiameterΦ14mm
Heating Element Length140mm
Adjustable Angle75°~120°
VoltageAC 220V / AC 110V, 50/60Hz
Power230W
Fuse250V, 2A/3A, Φ5x20
DimensionW.87 x D.151 x H.160mm
Net Weight1kgs

Features

Based on the principle of electronic infrared, the products are widely used in the sterilization of inoculation rings or inoculation needles, completely replacing alcohol lamps.
The temperature inside the heating hole can reach 800 °C or above, sterilization takes only 5-7 seconds and sterilization is thorough. The product can be used in an anaerobic chamber.
Small volume, light weight, appearance and easy to clean. Heating body can adjust angle, easy operation.
Organic substances in the ceramic funnel pipe depths ashing prevent infectious spatter and cross contamination.
Precise temperature control technology, avoid the heating components work overload, long life.

Photos

Operating Manuals

Download Manual (PDF)

1. Introduction
    1.1 Structure Description
2. Safety
3. Operation
4. Maintenance
5. Parameter
6. Packing list
7. Warranty
8. Warranty explanation
    Warranty content
    Warranty coverage

1. Introduction

The Bacti-Cinerator Sterilizer is a gasless ,flameless sterilizer for use with inoculating loops and needles.

Sterilization is accomplished through infrared heat without dangerous spattering of microorganisms.

Before starting up this unit for the first time, please read the rest of this operation manual.

1.1 Structure Description

Tags:, Description:, Attributes-End, The Bacti-Cinerator Sterilizer is a gasless ,flameless sterilizer for use with

Figure 1


Figure 2, The operator should not attempt to open or repair the instrument. Doing it may void your warranty or subject to

Figure 2

2. Safety

Figure 2, The operator should not attempt to open or repair the instrument. Doing it may void your warranty or subject to The operator should not attempt to open or repair the instrument. Doing it may void your warranty or subject to electric shocks. The company will responsible for the maintenance.

To avoid electric shock, the instrument input power cord must be grounded. This instrument uses a three-wire grounded plug, should be with the grounding-type power outlet.


Figure 2, The operator should not attempt to open or repair the instrument. Doing it may void your warranty or subject to If the power cord is damaged, it must be replaced by the same type cord. The power line do not close to anything. Do not place the power cord on the road.

Handheld plug the power cord plug. Should ensure that the plug is fully inserted into the socket and pull the plug instead of the cord.


During the normal operation, the heating body's temperature will be very high. There is possible to cause burns during the During the normal operation, the heating body's temperature will be very high. There is possible to cause burns during the whole operation. Don't touch the surface of the instrument with any part of the heating body, so as not to be burnt!

3. Operation

3.1 Remove any packaging that protects the Bacti-Cinerator Sterilizer from being damaged during forwarding.

3.2 Plug the electrical cord into the appropriate outlet. The unit must be properly grounded.

3.3 The red indicator will light up when the switch is pressed to the "High" side. The optimum sterilizing temperature(825°C) will be reached in 20 minutes.


Note: If the unit keep the sterilizing temperature (825°C)

over three hours, please set the switch in "Low" side for half an

hour. After 30 minutes, it can be switched to "High" side again. This will conserve the life of the heater element too. The green indicator will light up when the switch is to the "Low" side.


3.4 Gently insert the loop or needle, attached to an insulated loop holder, into the heater element. Avoid scraping the sides of the element to ensure the longevity of your loop and heater element. The loop should remain in the heater element not too long, 5-7 seconds is enough.

Make sure your glass culture tube with nothing in it.

3.5 Keep the input voltage between AC210-230V. When the input voltage exceed 230V, please stop using the equipment. It will conserve the life of the heater element.

3.6 Adjust the heating body angle

3.6.1. Loose the M3 screw by counterclockwise rotation with allen wrench

3.6.2. Adjust the angle of the heating body;

3.6.3. After adjusting the angle, tight the M3 screw by clockwise rotation.


Figure 3, 4.1 Only insulated loop holders should be used when inserting inoculating loops or needles into the heater

Figure 3

4. Maintenance

4.1 Only insulated loop holders should be used when inserting inoculating loops or needles into the heater element.

4.2 The Bacti-Cinerator Sterilizer is not intended for use with scalpels, forceps or any sharp objects. The use of such objects can cause element malfunction and void the heater element warranty.

4.3 Visual inspection of the heater element should be performed periodically to determine if the heater element core is worn. Inspect for small cracks and residue buildup in both the cool and heated conditions. In the heated condition, cracks can be seen as small, intensely yellow-orange fissures. If any defects are noted, the heater element should be replaced before element malfunction occurs.

4.4 The inoculating loops and needles should not be allowed to set in the heater element for extended periods of time. It will cause the loop holder to become extremely hot and increase the wearing of the loops and needles.

4.5 The red indicator light will come on when the switch is in the "High" position. Twenty minutes after the Bacti-Cinerator Sterilizer is plugged in ,the optimum sterilizing temperature(825°C) will be reached.

4.6 Notice: If the net power output voltage is greater than 10% of the rated voltage, turn off the power and stop using the machine.

5. Parameter

Model

BSTE-102

Power suply

AC220 V~ 50-60Hz

Power

135W

Highest temperature at core

825C 50C

Largest possible diameter of item to be sterilized

Φ14mm

Length of heating area

150mm

Heating time

20min

Fuse

250V 3A 5X20

Ambient temperature

5C ~40C

Dimension(WxDxH)

151x87x160 mm

Net weight

1.3kg

Table 1

6. Packing list

No.

Content

Model

Quantity

1

Bacti-Cinerator Sterilizer

BSTE-102

1

2

Operation Manual

1

3

Fuse

250V 3A (BSTE-102 )

1

4

Certificate

1

Table 2

7. Warranty

Thank you for the using of our products, we will provide comprehensive after-sales service in accordance with the Consumer Protection Act.

Please fill in the following information:


Item

BACTI-CINERATOR STERILIZER

Model

BSTE-102

Table 3


Customer company

Customer name

Customer address

Customer tel

Customer fax

Postal code

E-mail

Table 4

8. Warranty explanation

Warranty content

Within a month from the delivery date, the cause of failure due to material and manufacturing defects, the Company will be responsible for the guarantee replacement.

Within 6 months from the delivery date, the cause of failure due to material and manufacturing defects for heating body, the company will prove to be defective instruments selected for repair or replacement .

Within 12 months from the delivery date, the cause of failure due to material and manufacturing defects for other parts, the company will prove to be defective instruments selected for repair or replacement.

Warranty coverage

Result of improper using, damage caused by unauthorized repair or modification are not covered by warranty.Over the warranty period, the appropriate fees collected.


Get Quote