Get Price
Automatic Nucleic Acid Extraction System BNPS-203
Automatic Nucleic Acid Extraction System is a fully automatic high-throughput equipment with automatic sample addition, nucleic acid extraction and PCR system configuration. With magnetic bead extraction reagents, it is suitable for automatic nucleic acid extraction and purification of 1-96 clinical samples of various types. The flexible automatic liquid...
- 1. Accurate pipetting, air pressure correction can adapt to extreme environments such as flat ground, plateau, island, etc., to ensure the accuracy of pipetting
- 2. 96 samples can be processed within 60 minutes, realizing high-throughput processing of samples, saving time and effort
- 3. Reagent position and PCR plate position, can be refrigerated at 4°C
- 4. With high-efficiency filter, ultraviolet disinfection and sterilization, and safety door functions, effectively prevent microbial pollution
- Up to 3-Year Product Warranty
- US & EU Compliance Standards
- Door-to-Door Shipping
Technical Specifications
Detailed operating and construction parameters for this model.
| Model | BNPS-203 |
| Extraction Method | Magnetic bead method |
| Working Mode | Automatic sampling + Nucleic acid extraction + PCR reaction system addition |
| Throughput | 1~96, linear slide type sample rack |
| Extraction Volume | 20~1000μl |
| Processing Time | Complete processing of 96 samples within 60 minutes (Related to reagents) |
| Magnetic Bead Recovery | ≥98% |
| Temp Range | RT~105°C, lysis and elution position |
| Temp Accuracy | 0.1°C |
| Heating Method | Dry bath heating |
| Heating Speed | RT~100°C ≤6min |
| Shaking Function | Up and down oscillation (1~5 gears adjustable) |
| Extraction Position | 6 (96-well deep well plate) |
| Robotic Arm | A robotic arm for adding samples and reagents |
| Pipetting Channel | 2 channels |
| Liquid Detection | Pneumatic liquid level detection principle, intelligent detection of blocked needle |
| Pipetting Tip | 50μl, 200μl,1000μl, disposable black conductive needle with filter element |
| Tip Amount | 2~3 tips/sample |
| Pipetting Accuracy - 10μl tip | 10μl, CV≤3.0%, Accuracy≤5.0% |
| Pipetting Accuracy - 50μl tip | 50μl, CV≤2.0%, Accuracy≤2.0% |
| Pipetting Accuracy - 100μl tip | 100μl, CV≤1.5%, Accuracy≤2.0% |
| Sample Volume | 2~1000μl |
| Working Zone | 2 PCR positions with cooling function; 6 tip positions; 2 reagent positions |
| Protective Function | Start up self-test, Power-off protection, High temp alarm, Over-temp protection, Tip removal protection |
| Disinfection Method | UV lamp(30W*1, 8W*1) |
| Illumination Lamp | 10W LED lamp |
| Audible Alarm | Yes (Red and blue blinking) |
| Safety Door Design | With safety lock function, program suspended if door opened |
| Display | 10.1 inch touch screen, Windows system |
| Scanning | Optional |
| Interface | LAN interface (Bi-direction LIS optional) |
| Contamination Control | Built-in air duct and HEPA filter |
| IAP Function | Firmware can be upgraded online |
| Power Supply | 110/220V, 50/60Hz |
| External Size(W*D*H) | 1420*850*1842mm |
| Package Size(W*D*H) | Main Instrument: 1535*970*1180, Base: 1540*970*1160 |
| Gross Weight | Main Instrument: 360kg, Base: 190kg |
Product Features
Key design, performance, usability, and safety advantages.
Extra Information View additional product guidance, technical notes, diagrams, and supporting information.
Product Performance:

Precision
The same HCV samples were repeatedly extracted for 10 times and analyzed by qPCR. CV<3%

Sensitivity
The HCV samples with the concentration of 151U/mL were extracted, and the detection rate was 10/10

Linear
The HCV positive samples were diluted with equal dilution, and the linear correlation coefficient was R² > 0.98

Cross Contamination
HCV positive and negative samples were cross-extracted without cross-contamination.