Automated Blood Culture System BBCS-105

Labstar Blood Culture System, Automated Blood Culture System
  • 60*4 independent incubator;
  • metal frame, independent heating;
  • Random placement and removal, workable for anonymous bottle culturing;
  • Modular design for bottle number increasing; - Specimen placement and
  • classification with a colorful light indication for easy recognization;
  • Original "heat capacity pool" design for perfect constant temperature cultivation;
  • Modular and low-resistance slide rail for friendly operation;
  • 15-inch full-touch screen and multi-axis swing arm bracket for easy touch and easy operation;
Old SKU: BJS1G1
Specifications Features Accessories For Purchase Get Quote

Specifications

ModelBBCS-105
Specimen position240 specimen for a single machine; 4 incubators, 60 specimens for a single incubator
Instrument scalabilityModular management mode, which can be expanded to 64 instruments (15360 bottle positions)
Heating and temperature controlDrawer type incubator, independent heating for effective temperature control
Operation interfaceGraphic display of bottle position on computer interface, display of culture process curve
Blind placementSupports blind placement and blind picking; supports anonymous bottle culture and distinguishes anonymous bottle shapes
BarcodeThe use of barcodes for bottle setting/removing is convenient and quick to avoid errors; and the double barcode design ensures the consistency of the specimen and the report.
Culture MethodConstant temperature, rotating and shaking culture
Testing MethodOptical detection + color development at the bottom of the bottle, using both technologies at the same time
Testing TimeThe instrument automatically detects and records each specimen every ten minutes, and forms a curve at the same time
Cultivation curveThe growth curve of specimen culture is displayed dynamically and in real time throughout the whole process, multiple alarm calculation modes, and accurate analysis and judgment results
Positive alarm timeMore than 90% of the positive specimens can be alarmed within 24 hours, and the specimens can be delayed on the machine
Alarm mechanismPerfect alarm processing mechanism, positive and negative status indication, error operation prompt
Alarm duration settingThe preset alarm duration can be modified (system default: 120 hours)
Specimen InformationProvide patient data input, growth process curve and other related information for unlimited storage, and provide query and statistics at any time
Quality SystemISO9001, ISO13485
After-Sales ServiceFree lifetime upgrade of operating software
Working Environment10°C-30°C, Relative humidity: ≤85%
PowerAC220V / 50Hz power: 650VA

Features

60*4 independent incubator;
metal frame, independent heating;
Random placement and removal, workable for anonymous bottle culturing;
Modular design for bottle number increasing; - Specimen placement and
classification with a colorful light indication for easy recognization;
Original "heat capacity pool" design for perfect constant temperature cultivation;
Modular and low-resistance slide rail for friendly operation;
15-inch full-touch screen and multi-axis swing arm bracket for easy touch and easy operation;

Automated Blood Culture System 240 specimen for a single machine; 4 incubators, 60 specimens for a single incubator Modular
Automated Blood Culture System 240 specimen for a single machine; 4 incubators, 60 specimens for a single incubator Modular

More accurate and rapid test results shorten TAT time:
More reliable result using principle of light reflection and absorption (Color metric Technology)
Solid heat weld pool provides a more stable culture temperature for each bottle by direct heating
Automatic swing oscillation culture accelerates microbial growth
Various algorithms cooperate with each other to ensure accurate and reliable results
Supports delayed placement and secondary incubation of culture bottle
Detection rate ≥90% of positive specimen within 24 hours
More accurate and rapid test results shorten TAT time: More reliable result using principle of light reflection and

Humanized hardware and software design for more convenient and easier operation:
Integrated touch screen design saves space.
Multi-drawer incubator design realizes independent heating and temperature control.
Modular design supports multi-instrument cascade expansion.
Graphical operation interface is easier to operate.
Powerful query statistics export function facilitates clinical data analysis.
Ergonomic design is more comfortable for users.
Humanized hardware and software design for more convenient and easier operation: Integrated touch screen design saves space.

Accessories For Purchase

Images
Name
Volume (ml)
Automated Blood Culture System 240 specimen for a single machine; 4 incubators, 60 specimens for a single incubator Modular
Adult Antibiotic Neutralization Culture Bottle
25 ml
Automated Blood Culture System 240 specimen for a single machine; 4 incubators, 60 specimens for a single incubator Modular
Pediatric Antibiotic Neutralization Culture Bottle
25 ml
Automated Blood Culture System 240 specimen for a single machine; 4 incubators, 60 specimens for a single incubator Modular
Anaerobic Antibiotic Neutralization Culture Bottle
25 ml

Get Quote