Atomic Absorption Spectrophotometer BFP-701

Atomic Absorption Spectrophotometer
Key Features
  • Light Source System
  • Automatic 8-lamp turret, automatic optimization and alignment;
  • 2 positions for High performance lamp;
  • 8-lamp power on and multiple lamp preheat at the same time;
  • Memory function of editing each lamp position freely, with no need to use coded lamps.
  • Optical System
  • Czerny-Turner monochromator, diffraction grating groove 1800 lines/mm;
  • Seven spectral bandwidths automatically setting and optimization;
SKU: BFP-701
Pricing & Resources
  • Up to 3-Year Product Warranty
  • US & EU Compliance Standards
  • Door-to-Door Shipping
Recently Shipped To: 🇵🇭 Philippines , 🇧🇩 Bangladesh , 🇬🇧 United Kingdom , 🇳🇵 Nepal
Get Quote Download Catalog
Specifications Features Get Quote

Technical Specifications

Detailed operating and construction parameters for this model.

ModelBFP-701
Wavelength Range170-900nm
Spectral Bandwidth0.02nm
Wavelength AccuracyBetter than ±0.10nm
Wavelength Repeatability≤ 0.05 nm
Baseline Stability60 min baseline drift: 0.0005 Abs; Instantaneous noise: 0.0005 Abs
Dynamic Baseline Stability30 min baseline drift: 0.001 Abs; Instantaneous noise: 0.001 Abs
ResolutionSpectral bandwidth deviation: 0.02 nm;
Valley-peak energy ratio25% (Mn at 279.5 nm and 279.8 nm)
Cu Detection Limit0.002 μg/mL
Cu Characteristic Concentration0.03 μg/mL/1%
Cu Precision0.25%
Background CorrectionBetter than 150 times
Dimensions1010 x 620 x 630 mm (L x W x H)
Weight115 kg

Product Features

Key design, performance, usability, and safety advantages.

Light Source System
Automatic 8-lamp turret, automatic optimization and alignment;
2 positions for High performance lamp;
8-lamp power on and multiple lamp preheat at the same time;
Memory function of editing each lamp position freely, with no need to use coded lamps.
Optical System
Czerny-Turner monochromator, diffraction grating groove 1800 lines/mm;
Seven spectral bandwidths automatically setting and optimization;
Casting optical platform, ultra-low deformation under high/low temperature thermal effects, comprehensively improve stability;
Double-beam optics deducts baseline drift, saves warm-up time, comprehensively improves stability and analysis accuracy;
Baseline drift is better than 0.001Abs under 8-hour continuous work.
Atomization system
Constant and transverse magnetic field Zeeman background correction system, with all-element, all-wavelength, high background correction ability, easily deducts background interference above 2 Abs;
Enhanced flame constant magnetic field intensity up to 1.0T, improving analytical sensitivity;
Automatic ignition and gas flow precision control; The element intelligent matching technology achieves the self-adaption of flame height and flow;
Alarm and automatic protection to fuel gas leakage, abnormal flow, insufficient air pressure and abnormal flame extinction in flame system;
Equipped with an emergency button to extinguish the flame quickly.
With the function of cooling water and temperature monitoring to protect the magnetic field system for reliable operation.
With the foot-operated reading function, the testing data can be easily read by stepping on the reading panel, freeing the operator's hands.
Software and Communication
Intelligent operation software compatible to Win7 & Win10;
One-key operation for instrument optimization, supporting multi-task analysis;
Automatic curve fitting, automatic re-slope, automatic concentration calculation, etc.;
Ethernet interface makes the communication more stable.