Get Price

Atomic Absorption Spectrophotometer BAAS-602

Atomic Absorption Spectrophotometer

An analytical technique used to measure the concentrations of elements in a sample. The system is incredibly sensitive and can detect down to micrograms (?g). It is performed by focusing a beam of known wavelength of ultraviolet (UV) light through a flame and into a detector.

Key Features
  • Six lamp flame method. With automatic safety protection function, anti-tempering automatic gas path protection, acetylene gas leak- age alarm, automatic shutdown system, abnormal automatic power-off.
SKU: BAAS-602
Old SKU: BJN1C1
Pricing & Resources
  • Up to 3-Year Product Warranty
  • US & EU Compliance Standards
  • Door-to-Door Shipping
Recently Shipped To: 🇱🇰 Sri Lanka , 🇵🇪 Peru , 🇧🇧 Barbados , 🇬🇾 Guyana
Get Quote Download Catalog
Specifications Features Applications Get Quote

Technical Specifications

Detailed operating and construction parameters for this model.

ModelBAAS-602
Wavelength Range190-900nm
Spectral Bandwidth0.1, 0.2, 0.4, 1.0, 2.0nm (automatic adjustable)
Wavelength Accuracy≤ 0.15nm
Grating1800 l/mm
Wavelength Repeatability± 0.1 nm
Baseline Stability≤ ±0.002 A /30 minutes (static), ≤ ±0.005 A /30 minutes (dynamic)
Light Source≤ 6 lamps automatic turret, automatic alignment
PowerDouble cathode power built-in high performance lamps
Flame atomizer
- Characteristic Concentration (Cu)0.015 μg/mL/1%
- Detection Limits (Cu)-0.002 μg/mL
- PrecisionRSD ≤ 0.5 %
- Combustion HeadMetal Titanium combustion head
- AtomizerEfficient glass atomizer
- Atomizing ChamberExplosion proof corrosion resistant material spray chamber
- Control SystemAutomatic PC control three light brick, automatic alignment, automatic optimization and automatic ignition
- Safety ProtectionWith automatic safety protection function, anti-tempering, automatic gas path protection, acetylene gas leakage alarm, automatic shutdown system, abnormal automatic power-off
- Background CorrectionDeuterium background correction: correction of the 1A background
Data processing
- Measurement MethodsFlame method, Hydride method
- Concentration Calculation MethodStandard curve method (1 - 3 times curve), automatic matching, the standard addition method
- Repetition Survey Frequency1-99 times, calculating the average value, standard deviation and relative standard deviations are given
- Results PrintParameters print, data and graphics print, export WORD and EXCEL document. Simple operation, lamp position rotating, automatic ignition through software
Communication InterfaceComputer and USB interface communication
Power Requirements220 V (+5 % ~ -10 %), 50/60 Hz; 5000 VA
Environment Temperature+15 °C ~ +35 °C
Relative Humidity20 ~ 80 %

Product Features

Key design, performance, usability, and safety advantages.

Six lamp flame method. With automatic safety protection function, anti-tempering automatic gas path protection, acetylene gas leak- age alarm, automatic shutdown system, abnormal automatic power-off.
Applications Explore common laboratory, research, industrial, and process applications.

Food and Beverage Industry, Water Analysis, Clinical Research, Pharmaceutical, Mining and Geology, Environmental Monitoring, Oil and Petroleum, Forensics.

Get Quote