Atomic Absorption Spectrophotometer BAAS-601

Atomic Absorption Spectrophotometer
An analytical technique used to measure the concentrations of elements in a sample. The system is incredibly sensitive and can detect down to micrograms (?g). It is performed by focusing a beam of known wavelength of ultraviolet (UV) light through a flame and into a detector.
  • Three lamp flame method. With automatic safety protection function, anti tempering automatic gas path protection, acetylene gas leak- age alarm, automatic shutdown system, abnormal automatic power-off.
Old SKU: BJN1B1
Specifications Features Applications Get Quote

Specifications

ModelBAAS-601
Grating1800 I /mm
Wavelength Range190-900 nm
Spectral Bandwidth0.1. 0.2. 0.4,. 1.0. 2.0 nm (automatic adjustable)
Wavelength accuracy≤ 0.15 nm
Wavelength repeatability± 0.1 nm
Baseline stability≤ ± 0.002 A /30 minutes (static) ≤ ± 0.005 A /30 minutes (dynamic)
Light source≤ 3 lamps automatic turret, automatic alignment
PowerDouble cathode power built-in high performance lamps
Flame atomizer
- Characteristic concentration (Cu)0.015 μg/mL/1%
- Detection limits (Cu)0.002 μg/mL
- PrecisionRSD ≤ 0.5 %
- Combustion headMetal Titanium combustion head
- AtomizerEfficient glass atomizer
- Atomizing chamberexplosion proof corrosion resistant material spray chamber
- Control systemAutomatic PC control three light brick, automatic alignment, automatic optimization and automatic ignition
- Safety protectionWith automatic safety protection function, anti-tempering automatic gas path protection, acetylene gas leak- age alarm, automatic shutdown system, abnormal automatic power-off.
- Background correctionDeuterium background correction: correction of the 1A background
Data processing
- Measurement methodsFlame method, Hydride method
- Concentration calculation methodstandard curve method (1 - 3 times curve),automatic matching, the standard addition method
- Repetition survey frequency1-99 times, calculating the average value, standard deviation and relative standard deviations are given
- Results printParameters print, data and graphics print, export WORD and EXCEL document. Simple operation, lamp position rotating, automatic ignition through software
Communication interfaceComputer and USB interface communication
Power requirements220 V (+5 % ~ -10 %), 50/60 Hz; 5000 VA
Environment temperature+15 °C ~ +35 °C
Relative humidity20 ~ 80 %

Features

Three lamp flame method. With automatic safety protection function, anti tempering automatic gas path protection, acetylene gas leak- age alarm, automatic shutdown system, abnormal automatic power-off.

Applications

Food and Beverage Industry, Water Analysis, Clinical Research, Pharmaceutical, Mining and Geology, Environmental Monitoring, Oil and Petroleum, Forensics.