Get Price

Atomic Absorption Spectrophotometer BAAS-601

Atomic Absorption Spectrophotometer

An analytical technique used to measure the concentrations of elements in a sample. The system is incredibly sensitive and can detect down to micrograms (?g). It is performed by focusing a beam of known wavelength of ultraviolet (UV) light through a flame and into a detector.

Key Features
  • Three lamp flame method. With automatic safety protection function, anti tempering automatic gas path protection, acetylene gas leak- age alarm, automatic shutdown system, abnormal automatic power-off.
SKU: BAAS-601
Old SKU: BJN1B1
Pricing & Resources
  • Up to 3-Year Product Warranty
  • US & EU Compliance Standards
  • Door-to-Door Shipping
Recently Shipped To: 🇵🇰 Pakistan , 🇹🇿 Tanzania , 🇨🇦 Canada , 🇺🇾 Uruguay
Get Quote Download Catalog
Specifications Features Applications Get Quote

Technical Specifications

Detailed operating and construction parameters for this model.

ModelBAAS-601
Wavelength Range190-900nm
Spectral Bandwidth0.1. 0.2. 0.4,. 1.0. 2.0nm (automatic adjustable)
Wavelength accuracy≤ 0.15nm
Grating1800 I /mm
Wavelength repeatability± 0.1 nm
Baseline stability≤ ± 0.002 A /30 minutes (static) ≤ ± 0.005 A /30 minutes (dynamic)
Light source≤ 3 lamps automatic turret, automatic alignment
PowerDouble cathode power built-in high performance lamps
Flame atomizer
- Characteristic concentration (Cu)0.015 μg/mL/1%
- Detection limits (Cu)0.002 μg/mL
- PrecisionRSD ≤ 0.5 %
- Combustion headMetal Titanium combustion head
- AtomizerEfficient glass atomizer
- Atomizing chamberexplosion proof corrosion resistant material spray chamber
- Control systemAutomatic PC control three light brick, automatic alignment, automatic optimization and automatic ignition
- Safety protectionWith automatic safety protection function, anti-tempering automatic gas path protection, acetylene gas leak- age alarm, automatic shutdown system, abnormal automatic power-off.
- Background correctionDeuterium background correction: correction of the 1A background
Data processing
- Measurement methodsFlame method, Hydride method
- Concentration calculation methodstandard curve method (1 - 3 times curve),automatic matching, the standard addition method
- Repetition survey frequency1-99 times, calculating the average value, standard deviation and relative standard deviations are given
- Results printParameters print, data and graphics print, export WORD and EXCEL document. Simple operation, lamp position rotating, automatic ignition through software
Communication interfaceComputer and USB interface communication
Power requirements220 V (+5 % ~ -10 %), 50/60 Hz; 5000 VA
Environment temperature+15 °C ~ +35 °C
Relative humidity20 ~ 80 %

Product Features

Key design, performance, usability, and safety advantages.

Three lamp flame method. With automatic safety protection function, anti tempering automatic gas path protection, acetylene gas leak- age alarm, automatic shutdown system, abnormal automatic power-off.
Applications Explore common laboratory, research, industrial, and process applications.

Food and Beverage Industry, Water Analysis, Clinical Research, Pharmaceutical, Mining and Geology, Environmental Monitoring, Oil and Petroleum, Forensics.

Get Quote

Human Verification
What product does Biolab not sell? *