2°C to 15°C Laboratory Refrigerator BJX-1302
- Temperature Control
- Microprocessor control, Large LED display inner temperature clearly, and with easy viewing.
- The inner temperature can be adjustable at the range of 2°C~15°C, with an increment of 0.1°C.
- Multiple sensors to display or control the temperature.
- Lock and password for protection to prevent arbitrary adjustment of operating parameters.
- Safety Control
- Malfunction alarms: high temperature alarm, low temperature alarm.
- Sensor failure, Power failure alarm.
- Up to 3-Year Product Warranty
- US & EU Compliance Standards
- Door-to-Door Shipping
Technical Specifications
Detailed operating and construction parameters for this model.
| Model | BJX-1302 |
| Capacity | 580L |
| Temperature range | 2~15°C |
| Cabinet Type | Upright |
| Climate Class | N |
| Cooling Type | Forced air cooling |
| Defrost Mode | Auto |
| Refrigerant | R290 |
| Cooling performance(°C) | 4 |
| Controller | Microprocessor |
| Display | LED |
| Alarm | Audible, Remote |
| Interior | Galvanized steel powder coating |
| Exterior | Galvanized steel powder coating (white) |
| Power Supply(V/HZ) | 220/50 |
| Power(W) | 280 |
| Power Consumption | 3.3 |
| Net/Gross Weight(approx) | 144kg/173kg |
| Interior Dimensions(W*D*H) | 660x690x1400mm |
| Exterior Dimensions(W*D*H) | 780x830x1965mm |
| Package Dimensions(W*D*H) | 820x880x2175mm |
| High/Low Temperature | Yes |
| Remote Alarm contact | Yes |
| Sensor Failure | Yes |
| Door Ajar | Yes |
| Door lock | Yes |
| Inner LED light | Yes |
| Power Failure | Optional |
| Caster | Yes |
| Test Hole | Yes |
| Shelves/Inner Doors | 5/- |
| Foaming/Glass Door | optional |
| USB Interface | optional |
| Temperature Recorder | optional |
Product Features
Key design, performance, usability, and safety advantages.
Applications Explore common laboratory, research, industrial, and process applications.
Auto Defrost, Forced-Air Circulation Suitable for hospitals, blood banks, epidemic prevention, animal husbandry areas, pharmaceutical companies and research institutes.
Designed to store pharmaceuticals, medicine, vaccines, biological materials, testing reagents and laboratory materials. Microprocessor control, Large LED display inner temperature clearly, and with easy viewing; The inner temperature can be
adjustable at the range of 2°C~15°C, with an increment of 0.1°C,
Multiple sensors to display or control the temperature.
Operating Manual View instructions, operating procedures, safety information, and maintenance guidance.
1. CAUTION!
2. Installation
2.1 Safety Information
2.2 Assembly
2.3 Positioning the Refrigerator
2.4 Ventilation
2.5 Power Supply
3. Product description
4. Introduction of integrated refrigeration unit
5. Operation
5.1 Access to power
5.2 Setting Temperature
5.3 Turn on/off the light(Refrigerated model)
6. Cleaning
6.1 Out of service
7. Maintenance
8. Disposal
1. CAUTION!
All internal adjustments and maintenance must be performed by qualified service personnel.
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Environmental Protection
Discarded electric appliances are recyclable and should not be discarded in the domestic waste! Please actively support us in conserving resources and protecting the environment by returning this appliance to the collection centers(if available).
Important operating and/or maintenance instructions. Read the accompanying text carefully.
Potential electrical hazards. Only qualified persons should perform procedures associated with this symbol.
Hot surface(s) present which may cause burns to unprotected skin or to materials which may be damaged by elevate temperatures.
Extreme temperature hazards, hot or cold. Use special handling equipment or wear special, protective clothing.
Always use the proper protective equipment (clothing,gloves,etc.) Always use it to dissipate extreme cold or heat and wear protective clothing. Always follow good hygiene practices.
Each individual is responsible for his or her own safety.
2. Installation
2.1 Safety Information
All electrical work must be executed by suitably qualified persons. When using any electrical appliance, safety precautions must always be observed.
• Do not use this appliance for other than its intended use. This product is intended for use as a beverage Medical Refrigerator. Consult your supplier for alternatives.
• Do not cover the front grille or block the rear air entry by placing object up against the cabinet.
• Please close attention, when used by or near children, infirm persons.
• Ensure adequate ventilation.
• Do not probe any openings.
• Do not touch any moving parts or hot surfaces.
• Regulations require that all electrical work be carried out by authorized persons. For your own safety and that of others please ensure this is done.
• Do not overload the power supply. Always ensure on the rating label. The rating label is located.
If have any problem, please consult a qualified electrician. Caution: Never use extension leads or multiple adaptors.
• If the mains supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified and skilled persons in order to avoid hazard.
• Disconnect the mains power supply before attempting any cleaning, removal of any covers, or maintenance work.
• Do not store explosive substances, such as aerosol cans with flammable propellant.
• Warning: Do not use mechanical devices or other means to accelerate the defrosting process. Defrosting is performed automatically.
• Warning: Do not damage the refrigeration circuit.
• Warning: Do not use electrical appliances inside the storage compartment of this appliance.
2.2 Assembly
• Remove the appliance from the packaging and peel off any protective film from all surfaces.
• Fit the shelf support clips onto the shelf support strips, making sure that the clips for each shelf are of the same height and that they are securely engaged on the support strip.
• Unwrapping each shelf carefully, to prevent damaging their protective coating or surface finish.
• Position the shelves onto the clips.
Please dispose of all waste packaging appropriately and in accordance with all local recycling laws.
WARNING : Do not overload the power supply. Always ensure that the power supply is adequate for the electrical requirements specified on the rating label and never use extension leads or multiple adaptors.
2.3 Positioning the Refrigerator
• Please position the cabinet carefully being careful not to bump it.
• The maximum recommended ambient temperature for this Refrigerator is 32°C
• Avoid positioning the appliance in direct sunlight or damp areas.
• Allow adequate space for the door(s) to fully open.
• Ensure that this Refrigerator is positioned on a level surface, so as to allow the door(s) to shut and seal correctly, as well as to allow proper drainage from the evaporator tray, to prevent any overflow. If necessary, adjust the screw feet of the appliance to make it level.
Note: If the unit has not been stored or moved in an upright position, let it stand upright for approximately 12 hours before operation.
2.4 Ventilation
• All models must have clear and unobstructed ventilation from the entire surface area of the front grille.
• The 2 and 3 door models may be built into an enclosure without the need for ventilation other than at the front.
• The single door of Medical Refrigerators must have a minimum ventilation space of 20mm at sides and rear.
•
WARNING : Failure to provide the minimum ventilation space will harm the
performance of your Medical Refrigerator could cause fire and will invalidate the warranty.
•
WARNING : Keep clear of obstruction all ventilation openings in the appliance enclosure or in the structure for building in.
2.5 Power Supply
The Refrigerator must be well grounded. Never ground the Refrigerator through a gas pipe, tap water pipe or the grounded wire of single-phase power supply etc. Never share same circuit with other appliances. Before plugging in your Medical Refrigerator for the first time make sure the power cable is free from damage and check that your voltage corresponds to that on the serial plate.
Once plugged in the display will show the temperature inside the Medical Refrigerator and the compressor will run late on (the indicator light of cooling will be on at the same time ). This temperature is the actual temperature recorded by the probes inside the Medical
Refrigerator and as the fridge cools to the set point (factory set at 4/-25°C) so the number on the display will descend accordingly. If power is cut off, wait for at least 5 minutes before
plugging the unit in again to avoid damaging the compressor.
3. Product description

Figure 1
4. Introduction of integrated refrigeration unit

Figure 2
• 3.1 The unit has the advantages of high efficiency, low noise, reasonable structure, simple operation, safe operation and so on.
• 3.2 The compressor, fan and refrigeration system accessories of the unit are imported from famous foreign companies, with good quality, accurate control and reliable performance.
• 3.3 It has strong adaptability to possible bad working conditions and simple maintenance.
• 3.4 A set of unit drives the refrigeration of the whole product with high efficiency.
5. Operation
This product is designed to operate at a recommended ambient temperature not more than 32°C.
5.1 Access to power
• Close the door of the appliance.
5.2 Setting Temperature
• Press down to decrease the set temperature.
• Press up to increase the set temperature.
5.3 Turn on/off the light(Refrigerated model)
The lamp is controlled by the lamp switch.
If you want to turn on the light while you do not open the door, you can turn on the switch.
6. Cleaning
•
WARNING : You must disconnect the plug before cleaning or maintenance.
• Do not use abrasive cleaning agents which may scratch and harm the delicate interior finishes of your appliance.
• Always wipe dry after cleaning.
• An agent or qualified technician must carry out repair if required.
• When cleaning the storage box, please use a soft cloth or sponge dipped in warm water (neutral detergent can be added) to clean the storage box.
• It is strictly forbidden to spray and wash with water to avoid affecting the electrical insulation performance.
• It is strictly prohibited to use hard brush, wire brush, detergent, gasoline, banana water, acetone and other organic solvents, hot water or acid, alkali, etc. to clean the storage box.
6.1 Out of service
• If the storage box is out of service for a long time, the power supply should be cut off and cleaned according to the above method, and the door should be opened to dry.
• In general, it is not necessary to stop using the storage box for a long time in order to avoid affecting the service life.
7. Maintenance
If your appliance develops a fault, please check the following table before making a call to the helpline.
Fault | Possible Cause | Action |
The appliance is not working | The unit is plugged in correctly | Check the unit is plugged in correctly |
Plug or lead is damaged | Call Our agent or qualified technician | |
Power supply | Check power supply | |
Internal wiring fault | Call Our agent or qualified technician | |
The appliance turns on, but the temperature is too high or too low | Filter or condenser blocked with dust | Clean filter or condenser |
Doors are not shut properly | Check doors are shut and seal are not damaged | |
Appliance is located near a heat source or air flow to the condenser is being interrupted | Move the appliance to a more suitable location | |
Ambient temperature is too high | Increase ventilation or move appliance to a Medical Refrigerator position | |
Insufficient airflow to the fans | Remove any blockages to the fans | |
Appliance is overloaded | Reduce the amount stored in the appliance | |
Factory default parameters adjusted | Call Our agent or qualified technician | |
The LED lights not working | Led light short Leaded damage | Call Our agent or qualified technician |
The appliance is unusually loud | The appliance is touching a neighboring object | Check installation position and change if necessary |
The appliance has not been installed in a level or stable position | Check installation position and change if necessary |
Table 1
8. Disposal
If in any doubt, please consult your Local Authority, contact us or contact the reseller from whom you purchased the appliance.