We combine ease of use with reliability for your routine analysis and research applications. Our product offers the measurement range of 190-1100nm at bandwidth of 1.8nm/4m which provides better performance and increases lab productivity. Its affordable price and availability of optional accessories make it a versatile addition to your lab.
  • Wavelength range: 190nm-1100nm
  • Optical System: Double beam optical system
  • Czerny-Turner diffraction monochromator having 1200 lines/mm grating
  • Bandwidth: 1.8nm/4nm
Instant Quote
Specification Features Applications Optional Accessories
Wavelength Range190-1100 nm
Wavelength Accuracy±0.5 nm
Wavelength Repeatability0.3 nm
Spectral Bandwidth4 nm
Photometric Range0-200 %T, -0.3 - 3.0 A, 0-9999 C
Photometric Accuracy±0.5 %T or ±0.004 A @ 1A
Stability0.0008 A/h @ 500 nm
Baseline Flatness±0.002 A
Scan SpeedHi, Med., Low, Max 3000 nm/min
Stray Light0.05 %T @ 220 nm, 360 nm
Light SourceTungsten and Deuterium Lamp
Optical SystemSingle Beam , Grating 1200 lines/mm
Gross Dimension (W/D/H)491x365x180 mm
Display5 inches LCD (320*240 dots)
Weight (Net/Gross)14 kg
Power SupplyAC110V/220V 50Hz/60Hz
  • Wavelength range: 190nm-1100nm
  • Optical System: Double beam optical system
  • Czerny-Turner diffraction monochromator having 1200 lines/mm grating
  • Bandwidth: 1.8nm/4nm
  • Detector: Silicon Photodiode
  • Wide Measurement Range with ultra-low Stray Light at highest Resolution: With its ultra-low stray light (≤0.05 %T (220nm, 340nm)) is achieved at wavelength range of 190 - 1100 nm
  • Multi-wavelength pinpoint test for simultaneous testing of up to 30 wavelengths
  • Flexibility with various sample size: A wide range of standard cuvettes can be use based on the sensitivity or sample volume requirements.
  • Sophisticated and simplified sample analysis software: The Sample analysis software deliver scanning, fixed wavelength analysis, quantitative analysis, data collection, storage, export, and reporting.
  • With additional feature of an easy access USB port available in the unit, which enables results to be stored directly to a USB memory stick for easy transfer of data.
  • USB data interface with online PC software ensures powerful function and data processing capabilities
  • Automatic 4-position cell holder and optional 7-position or 16-position cell holder
  • Variety of optional accessories suitable for different applications including reflection sample holder, solid sample holder, water bath and auto sampler
Ideal for life science, QA, pharmaceuticals, clinical, environmental and general quality control applications.
Accessory CodeNameDescriptionUnitLight Path (mm)
3000806007Holder4-cell holder for up to 50mm square cuvette
3000806008Holder4-cell holder for up to 100mm square cuvette
3000806009HolderLong path single cell holder for 100mm
3000806010HolderSingle cell holder for 10mm square Cuvette
3000806011HolderCylindrical cell holder(Φ16mm)
3000806019Other5° reflectance meachment attachment (minimum sample:20x20mm ;central beam height:50mm)/1pc
3000806020Lamp6v10w halogen lamp/1pc
3000806021Lamp12v20w halogen lamp (phillips)
3000806022Lamp12v20w halogen lamp (osram)
3000806023LampMilas deuterium lamp; 10v;300ma; 30w
3000806024LampDeuterium lamp/1pc
3000806025Thermo printer
3000806026Stylus printer
3000806027CuvettesSquare cuvettes; glass 10mm/4pcs
3000806028CuvettesSquare cuvettes; glass 20mm/4pcs
3000806029CuvettesSquare cuvettes; glass 30mm/4pcs
3000806030CuvettesSquare cuvettes; glass 50mm/4pcs
3000806031CuvettesSquare cuvettes; glass 100mm/4pcs
3000806032CuvettesSquare cuvettes; quartz 10mm/2pcs
3000806033CuvettesSquare cuvettes; quartz 20mm/2pcs
3000806034Cuvettes500ul micro cell ; central-beam height:8.5mm;15mm; 2x10x45mm; quartz/1pc
3000806035Cuvettes1000ul micro cell; central-beam height:8.5mm;15mm; 3x10x45mm; quartz/1pc
3000806036SoftwareDongles for 31.61 application software ; (UV analyst software)/1set
3000806037SoftwareSoftware (m.wave basic)/1set
3000806038SoftwareSoftware/1set
3000806039SoftwareAdvanced PC window software (m.wave professional)/1set
3000806040SoftwareSoftware (m.wave basic)/1set
3000806041HolderCell holder for micro cells; Central beam height: 15mm
3000806042USB connector lineUSB connector line (only for m.wave basic)/1pc
3000806043Quartz CuvetteCell; 100ul; 1pcs; central beam height: 15mm10
3000806044Quartz CuvetteCell; 200ul; 1pcs;central beam height:15mm10
3000806045CuvetteFlow cell; 5 mm; optical glass; 1pcs;central beam height:15mm; l5xw2xh5mm
3000806046CuvetteFlow cell; 10 mm; optical glass; 1pcs;central beam height:15mm; l10xw2xh5mm
3000806047CuvetteFlow cell; 20 mm; optical glass; 1pcs;central beam height:15mm;l20xw2xh5mm
3000806048CuvetteFlow cell; 30 mm; optical glass; 1pcs;central beam height:15mm; l30xw2xh5mm
3000806049CuvetteFlow cell; 5 mm; quartz; 1pcs; central beam height:15mm; l5xw2xh5mm
3000806050CuvetteFlow cell; 20 mm; quartz; 1pcs; central beam height:15mm; l20xw2xh5mm
3001807006OtherA-102 peltier system; constant-temperature system; holder beam height:15mm
3000806052OtherA-100 peltier/sipper system; constant-temperature sipper system; holder beam height:15mm
3001808008Holder4-cell holder for 10mm to 50mm square cuvette
3001806009Holder4-cell holder for up to 100mm square cuvette
3000806054Holder10mm water-jacketed 4-cell holder
3000806055HolderTest tube holder(Φ8-Φ22mm)
3000806056HolderSolid sample holder(δ1.5mm-3mm; 1-position)
3000806057Silicon tubeSilicon tube; 1bag=1pair(1m+1m)/1bag
3000806060Glass cuvettesSquare cuvettes; volume:900ul2
3000806061Glass cuvettesSquare cuvettes; volume:450ul1
3000806062Quartz cuvettesSquare cuvettes; volume:1800ul/2pcs5