Portable pH/ORP Meter BMET-1301

Portable pH/ORP Meter BMET-1301

  • Sea, Air, Door to Door Shipping
  • 1 Year Warranty
  • US & European Standards
Multi-parameter Analyzer simultaneously measures Ion, Conductivity, Dissolved Oxygen, Temperature that otherwise requires four different meters. With the appropriate probes installed, it can also simultaneously measure several or one parameters.
  • pH
  • 1 to 5 points push-button calibration with auto-buffer recognition
  • Selectable pH buffer group (USA / NIST / DIN) or using the custom calibration solutions
  • Automatic electrode diagnosis with pH slope and offset display
Specification Features
pH Measuring Range- 2 ~ 20 pH
Temperature Measurement Range0 ~ 105 °C, 32 ~ 221 °F
pH Resolution0.001, 0.01, 0.1
mV Measuring Range± 1999.9 mV
Temperature Accuracy± 0.5 °C, ± 0.9 °F
pH Basic Error± 0.002 pH
Basic Error± 0. 2mV
pH Calibration Points1 ~ 5 points (USA, NIST, DIN, Custom)
Temperature CompensationAutomatic/Manual 0 ~ 100 °C, 32 ~ 212 °F
Storage CapacityStores up to 500 data sets
Temp Calibration Points1 point
Calibration Due Alarm1 ~ 31 days
Hold FunctionManual or Automatic endpoint detection
Stability CriteriaLow or High
mV Calibration Points1 point (Only for Relative mV mode)
OutputUSB communication interface
Dimensions and Weight170 (L) × 85( W) × 30 (H) mm
Weight300 g
Standard accessoriespH electrode, temperature probe, pH buffer solutions ( 4.01 / 7.00 / 10.01 ), carrying case
Power Supply3 × 1.5 V AA batteries or DC5 V power adapter
  • pH
  • 1 to 5 points push-button calibration with auto-buffer recognition
  • Selectable pH buffer group (USA / NIST / DIN) or using the custom calibration solutions
  • Automatic electrode diagnosis with pH slope and offset display
  • Automatic Temperature Compensation provides accurate reading over the entire range
  • Calibration Due Reminder prompts user to calibrate the meter regularly
  • ORP
  • 1 point offset calibration allows adjusting the displayed value to a known standard
  • Relative and absolute millivolt modes provide the reliable ORP measurements
  • GENERAL
  • Stability indicator shows when a measurement is recognized as stable
  • Auto-Hold feature senses and locks the measurement endpoint
  • Setup menu allows setting the 9 parameters, including the pH buffer group, number of calibration points, resolution, stability criteria, auto-power off, etc
  • Reset feature automatically resumes all settings back to factory default options
  • Expanded memory stores and recalls up to 500 data sets
  • Stored readings can be transferred into the computer by USB communication interface
  • Multi-mode power scheme (battery, power adapter or USB port) ensures that use the meter smoothly