Portable pH/ORP Meter BMET-1301
- Sea, Air, Door to Door Shipping
- 1 Year Warranty
- US & European Standards
Multi-parameter Analyzer simultaneously measures Ion, Conductivity, Dissolved Oxygen, Temperature that otherwise requires four different meters. With the appropriate probes installed, it can also simultaneously measure several or one parameters.
- pH
- 1 to 5 points push-button calibration with auto-buffer recognition
- Selectable pH buffer group (USA / NIST / DIN) or using the custom calibration solutions
- Automatic electrode diagnosis with pH slope and offset display
Specification
Features
pH Measuring Range | - 2 ~ 20 pH |
Temperature Measurement Range | 0 ~ 105 °C, 32 ~ 221 °F |
pH Resolution | 0.001, 0.01, 0.1 |
mV Measuring Range | ± 1999.9 mV |
Temperature Accuracy | ± 0.5 °C, ± 0.9 °F |
pH Basic Error | ± 0.002 pH |
Basic Error | ± 0. 2mV |
pH Calibration Points | 1 ~ 5 points (USA, NIST, DIN, Custom) |
Temperature Compensation | Automatic/Manual 0 ~ 100 °C, 32 ~ 212 °F |
Storage Capacity | Stores up to 500 data sets |
Temp Calibration Points | 1 point |
Calibration Due Alarm | 1 ~ 31 days |
Hold Function | Manual or Automatic endpoint detection |
Stability Criteria | Low or High |
mV Calibration Points | 1 point (Only for Relative mV mode) |
Output | USB communication interface |
Dimensions and Weight | 170 (L) × 85( W) × 30 (H) mm |
Weight | 300 g |
Standard accessories | pH electrode, temperature probe, pH buffer solutions ( 4.01 / 7.00 / 10.01 ), carrying case |
Power Supply | 3 × 1.5 V AA batteries or DC5 V power adapter |
- pH
- 1 to 5 points push-button calibration with auto-buffer recognition
- Selectable pH buffer group (USA / NIST / DIN) or using the custom calibration solutions
- Automatic electrode diagnosis with pH slope and offset display
- Automatic Temperature Compensation provides accurate reading over the entire range
- Calibration Due Reminder prompts user to calibrate the meter regularly
- ORP
- 1 point offset calibration allows adjusting the displayed value to a known standard
- Relative and absolute millivolt modes provide the reliable ORP measurements
- GENERAL
- Stability indicator shows when a measurement is recognized as stable
- Auto-Hold feature senses and locks the measurement endpoint
- Setup menu allows setting the 9 parameters, including the pH buffer group, number of calibration points, resolution, stability criteria, auto-power off, etc
- Reset feature automatically resumes all settings back to factory default options
- Expanded memory stores and recalls up to 500 data sets
- Stored readings can be transferred into the computer by USB communication interface
- Multi-mode power scheme (battery, power adapter or USB port) ensures that use the meter smoothly