Multi-parameter Analyzer BMET-607
- Sea, Air, Door to Door Shipping
- 1 Year Warranty
- US & European Standards
Multi-parameter Analyzer simultaneously measures Ion, Conductivity, Dissolved Oxygen, Temperature that otherwise requires four different meters. With the appropriate probes installed, it can also simultaneously measure several or one parameters.
Specification
Features
pH: | |
Range | - 2.00 to 20.00 pH |
Resolution | 0.1, 0.01 pH |
Accuracy | ± 0.01 pH |
Calibration Points | Up to 5 |
Standard Customization | Yes |
Standard Recognition | NIST, GB and DIN buffers |
mV: | |
Range | - 2000.00 to 2000.00 mV |
Resolution | 0.1 |
Accuracy | ± 0.3 mV or ± 0.1 % |
pX: | |
Range | - 2.00 to 20.00 |
Resolution | 0.1, 0.01 pX |
Accuracy | ± 0.02 pX |
Calibration Points | Up to 5 |
ISE: | |
Range | 1E-9 to 9.999E9 |
Unit | mol/L, mmol/L, g/L, mg/L, μg/L, ppm |
Resolution | Up to 4 significant digits |
Accuracy | ± 0.5 % |
Calibration Points | Up to 5 |
Conductivity: | |
Range | 0.000 μS/cm to 1000 mS/cm |
Resolution | 0.001 μS/cm minimum; changed with range |
Accuracy | ± 1.0 % FS |
Reference Temperature | 20, 25 °C |
Calibration Points | Up to 3 |
Standard Recognition | 84 μS/cm, 1413 μS/cm; 12.88 mS/cm |
Resistivity: | |
Range | 5.00 Ωcm ~20.00 MΩcm |
Resolution | 0.01 Ωcm minimum; |
Accuracy | ± 1.0 % FS |
TDS: | |
Range | 0.00 mg/L ~300 g/L |
Resolution | 0.01 mg/L minimum; changed with range |
Accuracy | ± 1.0 % |
Salinity: | |
Range | (0.00 ~8.00) % |
Resolution | 0.01 % |
Accuracy | ± 0.2 % |
Dissolved Oxygen Concentration: | |
Sensor Type | Polarographic |
Range | 0.00 to 50.00 mg/L |
Resolution | 0.01 mg/L |
Accuracy | ± 0.3 mg/L |
Calibration Points | Air-saturated water or zero point |
Barometric Compensation | Yes |
Manual Salinity Factor Correction | Yes |
Saturation: | |
Resolution | 0.10 % |
Accuracy | ± 10.0 % |
Temperature: | |
Range | - 5 to 110 °C, 23 to 230 °F |
Unit | °C, °F |
Resolution | 0.1 |
Relative Accuracy | ± 0.2 |
Measurement: | |
Reading Mode | AutoRead( Fast, Medium, Slow), Timed, Continuous |
Reading Prompts | Reading, Stable, Locked |
Temp. Compensation | ATC, MTC |
Data Management: | |
Data Storage | 1000 results each |
GLP Features | Yes |
Inputs: | |
pH Electrode | BNC(Q9) |
Temp./DO Probe | 4-pin aviation connector |
Temp./EC. Probe | 5-pin aviation connector |
Outputs: | |
USB | USB 2.0 flash memory device, PC,scanner |
Display Options: | |
Backlight | Yes |
Auto Shutdown | 300, 600, 1200, 1800, 3600 sec, off |
IP Rating | IP65 |
Yes | General: Power |
General: | |
Dimensions | 90x255x40 mm |
Weight | 500 g(1.1 lb) |