Multi-parameter Analyzer BMET-604
- Sea, Air, Door to Door Shipping
- 1 Year Warranty
- US & European Standards
Multi-parameter Analyzer simultaneously measures Ion, Conductivity, Dissolved Oxygen, Temperature that otherwise requires four different meters. With the appropriate probes installed, it can also simultaneously measure several or one parameters.
Specification
Features
pH: | |
Range | -3.000 to 20.000 pH |
Resolution | 1.1, 0.01, 0.001 pH |
Accuracy | ± 0.002 pH |
Calibration Points | Up to 7 |
Standard Customization | Yes |
Standard Recognition | NIST,GB,DIN,USA and MERK buffers |
Slope Limit | Yes |
mV/ORP: | |
Range | -2000.00 to 2000.00 mV |
Resolution | 0.1, 0.01 mV |
Accuracy | ± 0.1 mV or ± 0.03 % |
EH ORP Mode | Yes |
ORP Calibration Points | 1~2 custom point (relative mV) |
pX: | |
Range | - 2.000 to 20.000 pX |
Resolution | 0.1, 0.01, 0.001 pX |
Accuracy | ± 0.002 pX |
Calibration Points | Up to 6 |
ISE: | |
Range | 0~19990 |
Unit | mol/L, mmol/L, g/L, mg/L, μg/L |
Resolution | Up to 4 significant digits |
Accuracy | ± 0.3 % |
Calibration Points | Up to 6 |
Conductivity: | |
Range | 0.000 μS/cm to 3000 mS/cm |
Resolution | 0.001 μS/cm minimum; changed with range |
Accuracy | ± 0.5 % FS |
Reference Temperature | 5, 10, 15, 18, 20, 25 °C |
Calibration Points | Up to 5 |
Standard Recognition | 146.5 μS/cm, 1408 μS/cm, 12.85 mS/cm, 111.3 mS/cm |
Resistivity: | |
Range | 5.00 Ωcm ~100.00 MΩcm |
Resolution | 0.01 Ωcm minimum; |
Accuracy | ± 0.5 % FS |
TDS: | |
Range | 0.000 mg/L ~1000 g/L |
Resolution | 0.001 ppm minimum; changed with range |
Accuracy | ± 0.5 % |
Salinity: | |
Type | NaCl % |
Range | (0.00 ~8.00) % |
Resolution | 0.01 % |
Accuracy | ± 0.1 % |
Dissolved Oxygen Concentration: | |
Sensor Type | Polarographic |
Range | 0.00 to 99.99mg/L |
Resolution | 2.01 mg/L |
Accuracy | ± 0.1 mg/L |
Calibration Reminder | Yes |
Calibration Points | Air-saturated water or zero point |
Barometric Compensation | Yes |
Manual Salinity Factor Correction | Yes |
% Saturation: | |
Range | (0.0 to 600)% |
Saturation: | |
Resolution | 0.10 % |
Accuracy | ± 10.0 % |
Temperature: | |
Range | - 5 to 130 °C |
Unit | °C, |
Resolution | 0.1 |
Accuracy | ± 0.1 |
Measurement: | |
Reading Mode | AutoRead( Fast, Medium, Slow), Timed, Continuous |
Reading Prompts | Reading, Stable, Locked |
Temp. Compensation | ATC, MTC |
Data Management: | |
Data Storage | 1000 Groups |
GLP Features | Yes |
Log Management | Yes |
Inputs: | |
pH Electrode | BNC(Q9) |
Temp./DO Probe | 6-pin MiniDIN |
Temp./EC. Probe | 8-pin MiniDIN |
Outputs: | |
USB,RS 232 | USB 2.0 flash memory device, printer, PC |
Display Options: | |
Backlight | Yes |
Auto Shut-down | 1~60 min, off |
IP Rating | IP54 |
Date and Time | Yes |
General: | |
Power | AC Adapter, 100-240 V AC input, DC24V output |
Dimensions | 280x280x130 mm |
Weight | 2500 g (5.51 lb) |