Atomic Absorption Spectrophotometer BAAS-606

Atomic Absorption Spectrophotometer BAAS-606

  • Sea, Air, Door to Door Shipping
  • 1 Year Warranty
  • US & European Standards
An analytical technique used to measure the concentrations of elements in a sample. The system is incredibly sensitive and can detect down to micrograms (?g). It is performed by focusing a beam of known wavelength of ultraviolet (UV) light through a flame and into a detector.
  • Eight lamp flame/graphite furnace integrated machine. Imported photomultiplier tube. The graphite tube damage, water flow air pressure and other alarmtemperature overheating protection.
Specification Features Applications
Light Source8 lamps automatic turret, automatic alignment
Power Supply110/220 V (+5% ~ -10%), 60/50 Hz; 5000 VA
Lamp CurrentPulsed power supply
Optical SystemLarge 1800 /mm grating ruling, full closed optical system
Wavelength Range185 - 900 nm. Automatically peak find,a key opticaloptimization function
Wavelength Accuracy± 0.15 nm
Wavelength Repeatability< 0.01 nm
Spectral Bandwidth0.1, 0.2, 0.4, 0.7, 1.0, 1.4, 2.0 nm (7 steps with automatic changeover)
Baseline Stability≤ ± 0.002A/30 min (Static) ≤ ± 0.004A/30min (Dynamic)
Absorbance Range0 - 4 A
Flame Analytical System: 
      Detector:Imported photomultiplier tube
      Burner Head:Full titanium combustion head, 50 mm or 100 mm general combustion head
      Atomization Chamber:Polymer explosion-proof spray chamber
      Nebulizer:Atomizer efficient glass atomizer, can also be customized
      Ignition Type:Microcomputer control, automatic ignition
      Gas Control:Automatic gas control system
      Detection Limits(Cu):0.002 µg/mL
      Precision:RSD ≤ 0.5%
Graphite Furnace Analytical System: 
      Heating Mode:Vertical heating
      Temperature Control Method:Vertical optical temperature monitoring graphite tube wall temperature
      Temperature Range:Room temperature to 3000 °C
      The Program:Automatic temperature control up to 20 order
      Temperature Control:The furnace enriched up to 20 times
      Characteristics Volume:0.4 x 10 - 12 g (Cd)
      Detection Limit: Graphite Furnace Analytical System:0.4 x 10 - 12 g (Cd)
      Precision:RSD ≤ 2%
      The Cooling Water:Can choose cooling water circulation system
      Safety:The graphite tube damage, water flow air pressure and other alarmtemperature overheating protection
  • Eight lamp flame/graphite furnace integrated machine. Imported photomultiplier tube. The graphite tube damage, water flow air pressure and other alarmtemperature overheating protection.
Food and Beverage Industry, Water Analysis, Clinical Research, Pharmaceutical, Mining and Geology, Environmental Monitoring, Oil and Petroleum, Forensics.