Home
Spectrophotometer
Atomic Absorption Spectrophotometer
Atomic Absorption Spectrophotometer BAAS-602
Atomic Absorption Spectrophotometer BAAS-602
- Sea, Air, Door to Door Shipping
- 1 Year Warranty
- US & European Standards
An analytical technique used to measure the concentrations of elements in a sample. The system is incredibly sensitive and can detect down to micrograms (?g). It is performed by focusing a beam of known wavelength of ultraviolet (UV) light through a flame and into a detector.
- Six lamp flame method. With automatic safety protection function, anti tempering automatic gas path protection, acetylene gas leak- age alarm, automatic shutdown system, abnormal automatic power-off
Specification
Features
Applications
Grating | 1800 I /mm |
Wavelength Range | 190-900 nm |
Spectral bandwidth | 0.1. 0.2. 0.4,. 1.0. 2.0 nm (automatic adjustable) |
Wavelength accuracy | ≤ 0.15 nm |
Wavelength repeatability: | |
± 0.1 nm | |
Baseline stability | ≤ ± 0.002 A /30 minutes (static) ≤ ± 0.005 A /30 minutes (dynamic) |
Light source | ≤ 6 lamps automatic turret, automatic alignment |
Power | Double cathode power built-in high performance lamps |
Flame atomizer: | |
Characteristic concentration (Cu): | 0.015 µg/mL/1%. |
Detection limits (Cu): | 0.002 µg/mL |
Precision: | RSD ≤ 0.5 % |
Combustion head: | Metal Titanium combustion head |
Atomizer: | Efficient glass atomizer |
Atomizing chamber: | explosion proof corrosion resistant material spray chamber |
Control system: | Automatic PC control three light brick, automatic alignment, automatic optimization and automatic ignition |
Safety protection: | With automatic safety protection function, anti tempering automatic gas path protection, acetylene gas leak- age alarm, automatic shutdown system, abnormal automatic power-off |
Background correction: | Deuterium background correction: correction of the 1A background |
Data processing: | |
Measurement methods: | Flame method, Hydride method |
Concentration calculation method: | standard curve method (1 - 3 times curve),automatic matching, the standard addition method |
Repetition survey frequency: | 1-99 times, calculating the average value, standard deviation and relative standard deviations are given |
Results print: | parameters print, data and graphics print, you can also export WORD, EXCEL document |
Simple and convenient operation, lamp position rotating, automatic ignition through software operating | |
Communication interface: | Computer and USB interface communication |
Power requirements: | |
220 V (+5 % ~ -10 %), 50/60 Hz; 5000 VA | |
Environment temperature: | |
+15 °C ~ +35 °C | |
Relative humidity: | |
20 ~ 80 % |
- Six lamp flame method. With automatic safety protection function, anti tempering automatic gas path protection, acetylene gas leak- age alarm, automatic shutdown system, abnormal automatic power-off
Food and Beverage Industry, Water Analysis, Clinical Research, Pharmaceutical, Mining and Geology, Environmental Monitoring, Oil and Petroleum, Forensics.